These f factors are acceptable for all slab on grade floors but you need to make sure.
Insulated concrete floor slab detail.
Ground bearing floors shall be of adequate strength and durability and use concrete mixed and reinforced as necessary to support floor loads safely and resist chemical and frost action.
Figures 4 9 through 4 11 and 4 15 show configurations with insulation on the exterior surface of the foundation.
The f factors for slab on grade floors are defined in standard 90 1.
In this section several typical slab on grade sections are illustrated and described.
Consult appendix a table a6 3 1 in the 2016 edition for a tabulation of assembly f factors for slab on grade floors based on the arrangement and rated r value of the applied insulation.
The layer of rigid foam insulation that separates the concrete foundation wall on the outside from the slab on the inside.
4 2 slab on grade construction details.
Roche has paused at an important detail.
This stops any thermal bridging across the walls leading to cold spots.
The climate the type of foundation whether the slab includes hydronic tubing for radiant heat and the severity of the local termite problem.
The target u value for a concrete ground floor slab is 0 22 and these days the insulation must be provided around the edge of the floor slab as well.
Where the heating is likely to be turned on and off such as in new build domestic properties and a faster thermal response is required the floating floor arrangement of insulation above the slab can be more appropriate.
Figures 4 12 through 4 14 show variations where the slab is the primary location for insulation.
Ground bearing concrete floor slabs should be at least 100mm thick including monolithic screed where appropriate.
Perimeter slab insulation heat loss through an insulated slab windows 33 roof ceiling 8 slab 15 6 doors 5 walls 39 insulation and fenestration criteria table 402 1 1 insulation and fenestration requirements by componenta climate zone fenestration u factorb skylightb u factor glazed fenestrationb e shgc ceiling r value wood frame wall r value.
Such spaces typically have a sound level concrete slab floor but lack sufficient floor insulation to achieve the thermal performance targets for new habitable rooms.
Martin holladay explains insulating a slab on grade in the energy smart details department.
The slab on grade design calls for double stud walls insulated with dense packed cellulose what roche believes is the most economical and practical approach for getting the walls to r 40 or beyond.